USAfixTM - Repair Guide (RG) - Master Email RG
- Check for Power to the Solution Pump
 Level of Difficulty - HIGH  Estimated Completion Time - 30 minutes
TASKI - SWINGO XP

Tools Required
Tool 
Screwdriver-flat tip
Screwdriver-phillips
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 LOCATE THE MACHINE TOOL THAT WAS ATTACHED TO THE KEY RING OF YOUR MACHINE. THIS TOOL WILL BE USED TO OPEN THE MACHINE. IF YOU DO NOT HAVE THIS TOOL, YOU CAN USE A LONG FLAT TIP SCREWDRIVER.

2 LOCATE THE LABEL ON THE LEFT SIDE OF MACHINE (STANDING IN OPERATOR POSITION). FOLLOW THE DIRECTIONS ON THE LABEL TO OPEN THE MACHINE.

3 FOLLOWING THE DIRECTIONS ON THE LABEL, INSERT THE MACHINE TOOL INTO THE MACHINE.

4 LOCATE THE SOLUTION PUMPS ON THE FRONT OF THE MACHINE.

5 REMOVE THE 3 SCREWS FROM THE POWER BOARD. LOCATE THE RED AND BLACK WIRES LABELED DR (DRIVE MOTOR RIGHT) AND DL (DRIVE MOTOR LEFT). PULL THESE CONNECTORS TO TEMPORARILY DISABLE THE DRIVE MOTORS. YOU WILL NEED TO DISCONNECT THE DRIVE MOTORS SO THE MACHINE DOESN'T MOVE.
Screwdriver-phillips

6 TO ACTIVATE THE MACHINE, TURN THE KEY ON AND PUSH THE SOLUTION BUTTON ON THE CONTROL PANEL. YOU WILL NEED TO BYPASS THE STEPBOARD SWITCH AS THE MACHINE WILL NOT ACTIVATE WITHOUT SOMEONE STANDING ON THE STEP BOARD. TO BYPASS THE STEP BOARD SWITCH, LOCATE THE STEP BOARD SWITCH UNDER STEP BOARD. INSERT SCREWDRIVER ABOVE SWITCH AND BELOW THE STEP BOARD.
Screwdriver-flat tip

7 DISCONNECT THE 2 WIRE CONNECTORS ON EACH OF THE SOLUTION PUMPS.

8 INSERT THE VOLT METER LEADS INTO THE WIRE CONNECTORS STILL ATTACHED TO THE PUMPS. THE VOLT METER SHOULD READ APPROX. 24 VOLTS. REPEAT FOR BOTH SOLUTION PUMPS. IF THE SOLUTION PUMPS ARE OKAY, REVERSE STEPS 3 THRU 7 TO REASSEMBLE THE MACHINE.
Volt meter (True RMS capable)